Specification:
Load
capacity : up to 1000 kg*.
No. of load cell : Two.
Cross Travel : up to 1000 mm*.
Horizontal day light : 450 mm*.
Speed : 2mm / minute to
500mm/minute.
Paint : Powder coated.
Power : 230 Volts, 50Hz, single
phase.
Direct display and printout through
embedded controller: Peak load,
Break load, Elongation at peak load,
Elongation at break load, Tensile
strength at peak load, Tensile strength
at break load, % elongation at peak
load, % elongation at break load,
Young’s modulus, Yield load, Yield
stress, Flexural stress, Flexural
modulus, Compression strength and Load
Vs Elongation graph could be obtained in
different user selectable unit and
format. Similarly average value and
standard deviation could be obtained by
merging different tests.
|